Cleanup, overnight storage and winter
· Airless Sprayer
Repair shops say most airless failures start with cleaning: paint dried in a valve, a clogged strainer, a pump left wet over winter. The fix is a routine, not a better machine.
Every day
- Relieve the pressure and lock the trigger.
- Move the suction tube to clean water (latex) or the solvent the coating names, and flush through the prime circuit into a waste pail.
- Flush through the gun until it runs clear.
- Clean the tip, guard, gun filter and inlet strainer by hand. Carry a spare filter and a spare tip.
Budget about 20 to 30 minutes. Never leave coating in the pump overnight.
Between days on the same job
Some crews leave latex in the hose overnight with the tip submerged; manuals generally say flush. If you skip a full flush, at least relieve pressure, cover the inlet and keep the machine out of frost. When in doubt, flush.
Long storage and winter
- Flush clean, then leave the pump-protector fluid the manual names in the pump.
- Store indoors above freezing. Water in the pump can freeze and crack parts; an unheated trailer in January is a risk.
- Store upright with the hose loosely coiled.
- Before the first job of spring, flush once more and check the strainer.
HVBAN specifics
The approved manual for each regional model names the storage fluid and filter meshes; we will link it from each model page before sale. Until then, the A3 getting-started guide covers the routine.
Photo: illustrative scene, not a customer photograph.