Power on the job site: circuits, cords and generators
· Airless Sprayer
Most "the sprayer keeps cutting out" stories are power stories. An electric airless motor pulls hard on start-up and every time the pump cycles back on to hold pressure.
The circuit
- Use a dedicated 15 A circuit where you can, and do not share it with a compressor, heater or saw.
- Check the nameplate amps on the machine. A motor rated around 2,000 W at 120 V draws more than 15 A, which is more than a 15 A circuit is meant to carry; at 1,500 W it is about 12.5 A.
- If a breaker trips repeatedly, stop and find out why. Do not swap in a bigger breaker.
The cord
- Use a heavy cord: 12-gauge is the common recommendation. Thin cords drop voltage, the motor works harder and pressure sags.
- Keep it as short as the manual allows. Run more paint hose instead of more cord, within the machine's maximum hose length.
Generators
Manufacturers publish a minimum generator size for each machine; for a typical small contractor unit it is a few thousand watts. Size for the start-up surge, not just the running watts, and keep the sprayer the only big load on it.
HVBAN models
We are confirming the North American nameplate amps, cord recommendation and minimum generator size for the EP270, A3 and LF19, and will publish them on each model page. Manufacturer listings for the EP270 currently show two different motor ratings; we will publish the confirmed nameplate before sale.